35KV transformer
Our Oil-Immersed Transformers offer a cost-effective solution for your network. Whether it is for managing aurban orrural network, or for simply improving your energy efficiency, or optimized cost efficiency solution to connect power plants to supply systems or to link together networks with different voltage levels, we have the perfect solution for any transformer application. Ground mounted, pole mounted or high-efficiency oil type transformers all form part of our extensive range.
Categories:
Oil Immersed Transformer
Specification
Our Oil-Immersed Transformers offer a cost-effective solution for your network. Whether it is for managing aurban orrural network, or for simply improving your energy efficiency, or optimized cost efficiency solution to connect power plants to supply systems or to link together networks with different voltage levels, we have the perfect solution for any transformer application. Ground mounted, pole mounted or high-efficiency oil type transformers all form part of our extensive range.
Configurations

1 | Oil filter valve | 17 | Oil drain valve |
2 | Conservator | 18 | Jacking boss |
3 | Buchholz relay | 19 | Stopper |
4 | Oil filter valve | 20 | Foundation bolt |
5 | Pressure-relief vent | 21 | Grounding terminal |
6 | High-voltage bushing | 22 | Skid base |
7 | Low-voltage bushing | 23 | Coil |
8 | Suspension lug | 24 | Coil pressure plate |
9 | B C T Terminal | 25 | Core |
10 | Tank | 26 | Terminal box for protective devices |
11 | De-energized tap changer | 27 | Rating plate |
12 | Tap changer handle | 28 | Dial thermometer |
13 | Fastener for core and coil | 29 | Radiator |
14 | Lifting hook for core and coil | 30 | Manhole |
15 | End frame | 31 | Lifting lug |
16 | Coil pressure bolt | 32 | Dial type oil level gauge |
Features and Advantages
Rated power up to 100 MVA
Rated insulation level up to 170 kV
Rated frequency 50 or 60 Hz
Mineral oil insulating liquid
Low flammability dielectric liquids
Hermetically sealed or breathing with conservator
Conventional or reduced losses
High capacity of cooling options such as ONAN, ONAF, OFAF or OFWF (also with K class insulating oil)
Off-Circuit Tap Changer (OCTC) or On-Load Tap Changer (OLTC)
Wide range of accessories
Rectifier feeder (Rectifier Transformers range)
High reliability in harsh environments
Customized design and bespoke manufacturing
Long service life with minimal maintenance
Available with MV & LV Switchboard
Ease of Installation
Applications
● Energy
● Infrastructure
● Commercial
● Utilities: Transmission and Distribution Network
● Power Generation: Hydro, Nuclear, Thermal…
● Small Industries: Textile, Automotive, Pharmaceutics, Food…
Renewable Energies: Solar, Wind onshore and offshore, Biomass…
Key words:
35KV transformer
Previous
Next
Previous
Next
Qualification Patent
Aisite Electric Group has passed CE, TYPE TEST, ISO9001, ROHS, REACH, CQC, GOST and many other authoritative certifications.
ISO 9001 2015
ISO 14001 2015
ISO 45001 2018
Product certification certificate
Product certification certificate
Get A Quote
Leave your contact information and get a free product quote
Related Products
Aisite Electric Group has passed CE, TYPE TEST, ISO9001, ROHS, REACH, CQC, GOST and many other authoritative certifications.
6 pulse high overload medium frequency furnace dedicated transformer
Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the Induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation.
12 pulse high overload medium frequency furnace dedicated transformer
Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the Induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation.
12 pulse heat sink high overload medium frequency furnace special transformer
Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the Induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation.
Induction Furnace Transformers
Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the Induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation.