S13 Series 10KV Transformer
As a manufacturer, we understand the relevance that logistics represents to our customers. This is one of the reasons why Aisite has developed a large and qualified net work of suppliers that have the same values and targets.
Categories:
Oil Immersed Transformer
Code and implication

Model | Rated power | Rated primary voltage | Tapping | Rated secondary voltage | Vector group | No-load losses | Load losses | No-load current | Rated impedance | |
Dy | Yy | |||||||||
S13-M-30 | 30 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 80 | 630 | 600 | 2.3 | 4 |
S13-M-50 | 50 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 100 | 910 | 870 | 2 | 4 |
S13-M-63 | 63 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 110 | 1090 | 1040 | 1.9 | 4 |
S13-M-80 | 80 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 130 | 1310 | 1250 | 1.9 | 4 |
S13-M-100 | 100 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 150 | 1580 | 1500 | 1.8 | 4 |
S13-M-125 | 125 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 170 | 1890 | 1800 | 1.7 | 4 |
S13-M-160 | 160 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 200 | 2310 | 2200 | 1.6 | 4 |
S13-M-200 | 200 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 240 | 2730 | 2600 | 1.5 | 4 |
S13-M-250 | 250 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 290 | 3200 | 3050 | 1.4 | 4 |
S13-M-315 | 315 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 340 | 3830 | 3650 | 1.4 | 4 |
S13-M-400 | 400 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 410 | 4520 | 4300 | 1.3 | 4 |
S13-M-500 | 500 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 480 | 5410 | 5150 | 1.2 | 4 |
S13-M-630 | 630 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 570 | 6200 | 6200 | 1.1 | 4.5 |
S13-M-800 | 800 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 700 | 7500 | 7500 | 1.0 | 4.5 |
S13-M-1000 | 1000 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 830 | 10300 | 10300 | 1.0 | 4.5 |
S13-M-1250 | 1250 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 970 | 12000 | 12000 | 0.9 | 4.5 |
S13-M-1600 | 1600 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 1170 | 14500 | 14500 | 0.8 | 4.5 |
S13-M-2000 | 2000 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 1510 | 17800 | 17800 | 0.8 | Customized |
S13-M-2500 | 2500 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 1780 | 20700 | 20700 | 0.7 | Customized |
S13-M-3150 | 3150 | 6/6.3/10/10.5 | ±2×2.5 | 0.4 | Yyn0 | 2100 | 24300 | 24300 | 0.7 | Customized |
Dimensions

Note: Dimensions are for guidance and reference only and are NON CONTRACTUAL.
Logistic and service
Once the transformer is successfully tested and qualified, the product is ready for shipping either by truck or sea-freight.
As a manufacturer, we understand the relevance that logistics represents to our customers. This is one of the reasons why Aisite has developed a large and qualified net work of suppliers that have the same values and targets.
Aisite takes care of all official documentation, depending on final destinations and delivery terms.
Different packaging for special applications or conditions:
- Standard packing
- Crate packing
- Seaworthy packing
Built for sturdiness and efficiency(Production process)
The core
The iron core forms the central element of every transformer. High-grade, cold-rolled metal sheets are precision-cut using computer-controlled machines to ensure compliance with even the smallest tolerances. The individual sheets are then assembled into cores using the step-lap technique by our veteran workers. In this way, weachieve an especially good flux distribution at the joints, resulting in exceptionally low losses and minimal no-load noise.

Windings
Transformer windings are subject to extremely high electrical and mechanical stresses and must therefore be protected. The transformer windings of our transformers are made of copper or aluminum. Low-voltage windings are made fromfoil, and high-voltage windings are manufactured from round orstripprofile wire. The use of insulating paper partially coated with epoxy resin (diamond-dotted paper) bonds the winding into a compact block during the drying process and additionally increases the short-circuit capacity.

Insulating liquids
The layer insulation is adapted to the alternating voltage strain that occurs in daily operation. Large-scale oil channels are provided to ensure sufficient cooling of the windings and to avoid hot spots. All leads are short-circuit-proof and surge-proof, contributing to the high reliability of thetransformer – and to an above-average service life.

Tank & Cooling
Whether during transport or operation, the tank must remain sealed tight under mechanical stress and regardless of wind or weather. Corrosion protection is especially important. The surface is sandblasted and then multicoated. Upon request, hot-dip galvanization can provide even better protection.
The distribution transformer’s tank must dissipate the entire heat loss. In hermetically sealed transformers, the corrugated walls absorb the changes in the insulation liquid’s volume. Alternatively, the transformer can be designed as an open system or fitted with an oil conservator that compensates for the additional volume.
Some regions also use smooth-walled tanks and built-in radiators. Hermetically sealed units sometimes have an air or gas cushion to compensate for oil expansion. The sheet-steel lid is bolted – or, upon request, welded – to the tank. The steel thickness and the bracing are dimensioned to ensure that the lid withstands all necessary stress.

Final assembly
The transformer’s core-and-coil assembly consists of the core, windings, and connecting cables. High-quality drying and quick filling with insulation oil play a key role in extending the transformer’s service life.Aisite employs the latest techniques. For example, in vacuum low-frequency plants (LFH – low-frequency heating), the process of drying the solid insulation is combined with vacuum drying of the windings through low-frequency heating. The active part is heated by applying low-frequency current (< 1 Hz) to the high-voltage windings with the low-voltage windings short-circuited. While still in the plant, transformers are filled with preheated insulation liquid which is absorbed by the insulation material, thus preventing the intake of oxygen.

Key words:
S13 Series 10KV Transformer
Qualification Patent
Aisite Electric Group has passed CE, TYPE TEST, ISO9001, ROHS, REACH, CQC, GOST and many other authoritative certifications.
ISO 9001 2015
ISO 14001 2015
ISO 45001 2018
Product certification certificate
Product certification certificate
Get A Quote
Leave your contact information and get a free product quote
Related Products
Aisite Electric Group has passed CE, TYPE TEST, ISO9001, ROHS, REACH, CQC, GOST and many other authoritative certifications.
6 pulse high overload medium frequency furnace dedicated transformer
Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the Induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation.
12 pulse high overload medium frequency furnace dedicated transformer
Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the Induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation.
12 pulse heat sink high overload medium frequency furnace special transformer
Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the Induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation.
Induction Furnace Transformers
Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the Induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation.